Protocol summary
-
Study aim
-
Determining the effects of using sound frequencies on the level of analgesia and hemodynamic disorders during intubation and extubation in patients under general anesthesia.
-
Design
-
The current study is a randomized double-blind clinical trial in phase 2 with a control group, which is conducted on 175 patients. The randomization of the samples is done using the order of random letters by computer software.
-
Settings and conduct
-
The study is conducted on elective candidates for general anesthesia in Imam Reza Hospital, Kermanshah. In the intervention groups, the application of different sound frequencies during the process of general anesthesia is done by headphones. The patients and the researcher who recorded the data do not know about the grouping and the type of intervention.
-
Participants/Inclusion and exclusion criteria
-
Patients who are under general anesthesia.
-
Intervention groups
-
In control group 1; patients do not receive any sound stimulation.
In control group 2; passive wireless headphones are placed on both ears of the patient so that the ambient sound intensity is less than 5 dB and the patient does not receive any sound stimuli. In the intervention groups: sound stimulation with frequencies of 5, 10, 20, 50 and 100 Hz from the time of entering the operating room until the patient leaves the recovery room through wireless headphones, receives sound stimulation with a sound intensity of 50 dB.
-
Main outcome variables
-
Changes in blood pressure; change in heart rate ; pain level; comfort; anxiety
General information
-
Reason for update
-
This update is being made to clarify and complete the registered information regarding the conduct of the study and to improve the consistency of the trial record with the study protocol and the actual procedures used during the study. These updates do not change the overall nature of the intervention or the main objectives of the study.
-
Acronym
-
-
IRCT registration information
-
IRCT registration number:
IRCT20240123060780N3
Registration date:
2024-06-08, 1403/03/19
Registration timing:
prospective
Last update:
2026-10-08, 1405/07/16
Update count:
1
-
Registration date
-
2024-06-08, 1403/03/19
-
Registrant information
-
-
Recruitment status
-
Recruitment complete
-
Funding source
-
-
Expected recruitment start date
-
2024-07-22, 1403/05/01
-
Expected recruitment end date
-
2025-07-23, 1404/05/01
-
Actual recruitment start date
-
empty
-
Actual recruitment end date
-
empty
-
Trial completion date
-
empty
-
Scientific title
-
The effects of using sound frequencies on analgesia level and hemodynamic disorders during intubation and extubation in patients under general anesthesia
-
Public title
-
Effects of sound frequencies on analgesia and hemodynamic changes
-
Purpose
-
Treatment
-
Inclusion/Exclusion criteria
-
Inclusion criteria:
Not having a history of underlying diseases such as blood pressure, diabetes, heart and lung diseases
Patients with American Society of Anesthesiology (ASA) classification 1 and 2
Airway grade 1
Not receiving premedication the night before and the morning of the operation
having full normal hearing (25 dB hearing threshold)
Having full consciousness
Exclusion criteria:
History of smoking and addiction
Having an ear infection and anatomical abnormalities of the auditory system
Non-cooperation of the patient
-
Age
-
From 20 years old to 50 years old
-
Gender
-
Both
-
Phase
-
2
-
Groups that have been masked
-
- Participant
- Care provider
- Outcome assessor
-
Sample size
-
Target sample size:
175
-
Randomization (investigator's opinion)
-
Randomized
-
Randomization description
-
Randomization of samples in this study is done by computer software.Due to the 7 groups, a random order of letters A, B, C, D, E, F, G is made in blocks with a random number of 7 letters. Each letter is a symbol of one of the study groups. Then these obtained blocks are placed in sealed envelopes. Before starting the study, one of the researchers opens one of the envelopes and finally the patient is placed in one of the intervention or control groups.
-
Blinding (investigator's opinion)
-
Double blinded
-
Blinding description
-
In Control Group 1, headphones were placed over the patient’s ears; however, the headphones had no audio function and contained openings over the ear area, allowing patients to hear environmental sounds naturally. In Control Group 2, intact but inactive headphones were placed over the patient’s ears, preventing the patients from hearing environmental sounds. In the intervention groups, intact headphones were used to deliver auditory stimulation at the specified frequencies. Because the headphones were visually identical and patients were unaware of their group allocation and the frequency of the auditory stimulation, patients were blinded to both group assignment and intervention frequency. An investigator involved in the project was responsible for administering anesthesia and managing the patients throughout the anesthetic period and was blinded to group allocation and stimulation frequency. Auditory stimulation was delivered through the headphones, with the stimulation frequency configured via the headphones’ Bluetooth connection. Another researcher responsible for recording the study variables was unaware of the patients’ group allocation and the frequency of auditory stimulation received and was blinded to both. Statistical analyses were performed after completion of data collection.
-
Placebo
-
Used
-
Assignment
-
Parallel
-
Other design features
-
Ethics committees
1
-
Ethics committee
-
-
Approval date
-
2024-01-30, 1402/11/10
-
Ethics committee reference number
-
IR.KUMS.REC.1403.102
Health conditions studied
1
-
Description of health condition studied
-
Pain
-
ICD-10 code
-
G89.1
-
ICD-10 code description
-
Acute pain, not elsewhere classified
2
-
Description of health condition studied
-
surgical pain
-
ICD-10 code
-
G89.18
-
ICD-10 code description
-
Other acute postprocedural pain
Primary outcomes
1
-
Description
-
Heart rate
-
Timepoint
-
It is measured immediately and at 1, 2, 3, 4, and 5 minutes after intubation and extubation.
-
Method of measurement
-
Using monitoring connected to the patient
2
-
Description
-
mean arterial pressure
-
Timepoint
-
It is measured immediately and at 1, 2, 3, 4, and 5 minutes after intubation and extubation.
-
Method of measurement
-
using a monitor connected to the patient.
3
-
Description
-
Anxiety
-
Timepoint
-
It is measured before induction of anesthesia.
-
Method of measurement
-
The visual analog scale
4
-
Description
-
comfort
-
Timepoint
-
It is measured before induction of anesthesia.
-
Method of measurement
-
The visual analog scale
5
-
Description
-
Pain
-
Timepoint
-
Before discharge from the recovery unit and at 1, 3, and 6 hours after surgery.
-
Method of measurement
-
The visual analog scale
6
-
Description
-
Systolic and diastolic blood pressure
-
Timepoint
-
Every 15 minutes during anesthesia and also before leaving the recovery room
-
Method of measurement
-
using a monitor connected to the patient
7
-
Description
-
Heart rate
-
Timepoint
-
Every 15 minutes during anesthesia and also before leaving the recovery room
-
Method of measurement
-
Using patient-connected monitoring
8
-
Description
-
Bispectral Index value during general anesthesia
-
Timepoint
-
Before induction of general anesthesia, after induction of general anesthesia, and at 15, 30, 45, and 60 minutes, as well as after extubation.
-
Method of measurement
-
Continuous monitoring using a bispectral index monitor with a disposable forehead sensor
Secondary outcomes
1
-
Description
-
The amount of narcotic drugs used for analgesia (morphin) in the recovery department
-
Timepoint
-
It is measured in the recovery section.
-
Method of measurement
-
In terms of milligrams of the drug injected by anesthesia personnel
Intervention groups
1
-
Description
-
Control 1 group: perforated wireless headphones are placed over both ears, and patients do not receive any auditory stimulus or stimulation intervention. The perforated headphones allow ambient sounds to remain audible.
-
Category
-
Placebo
2
-
Description
-
Control 2 group: passive wireless headphones are placed over both ears to reduce the intensity of ambient sound to less than 5 dB, and patients in this group do not receive any sound stimuli.
-
Category
-
Placebo
3
-
Description
-
Intervention group: patients receive sound stimulation with a frequency of 5 Hz and sound intensity of 50 dB through wireless headphones.
-
Category
-
Treatment - Devices
4
-
Description
-
Intervention group: patients receive sound stimulation with a frequency of 10 Hz and sound intensity of 50 dB through wireless headphones.
-
Category
-
Treatment - Devices
5
-
Description
-
Intervention group: patients receive sound stimulation with a frequency of 20 Hz and sound intensity of 50 dB through wireless headphones.
-
Category
-
Treatment - Devices
6
-
Description
-
Intervention group: patients receive sound stimulation with a frequency of 50 Hz and sound intensity of 50 dB through wireless headphones.
-
Category
-
Treatment - Devices
7
-
Description
-
Intervention group: patients receive sound stimulation with a frequency of 100 Hz and sound intensity of 50 dB through wireless headphones.
-
Category
-
Treatment - Devices
1
-
Sponsor
-
-
Grant name
-
-
Grant code / Reference number
-
-
Is the source of funding the same sponsor organization/entity?
-
Yes
-
Title of funding source
-
Kermanshah University of Medical Sciences
-
Proportion provided by this source
-
100
-
Public or private sector
-
Public
-
Domestic or foreign origin
-
Domestic
-
Category of foreign source of funding
-
empty
-
Country of origin
-
-
Type of organization providing the funding
-
Academic
Sharing plan
-
Deidentified Individual Participant Data Set (IPD)
-
Undecided - It is not yet known if there will be a plan to make this available
-
Study Protocol
-
No - There is not a plan to make this available
-
Statistical Analysis Plan
-
No - There is not a plan to make this available
-
Informed Consent Form
-
No - There is not a plan to make this available
-
Clinical Study Report
-
No - There is not a plan to make this available
-
Analytic Code
-
No - There is not a plan to make this available
-
Data Dictionary
-
No - There is not a plan to make this available